Item TF-0ABE4T5
Automatic Ring and Ball Tester
- Brand
- IPC Global
- Configuration
- Automatic · optical detection

The Automatic Ring and Ball Tester allows fully automatic performance of softening point determination of binders conforming to most common international Standards.
Technical specifications
| Test places | 2 |
|---|---|
| Temperature range | up to 250°C |
| Temperature probes | PT100 probe,, range -30 +350°C, 0.1°C resolution, ±0.2 °C accuracy; K thermocouple for hotplate monitoring range from 0°C to +1000°C, 0.1° resolution |
| Stirrer speed | from 0 to 200 rpm |
| Safety features | Integrated cooling fan; Removable front protection cover; Temperature warning icon; Included PT100 probe holder and drip tray for specimen holder |
| Electronic controller specifications | 7” color capacitive touch screen graphical display, 16M color and 800 x 480 px resolution; Possibility to set up to 10 personalized test profiles; Possibility to program used custom tests with user defined end test conditions (up to 250°C) and temperature gradient up to 6°C/min; Display of temperature/time graph in real-time, and softening point temperature of the two specimens; Possibility the set the language among 14 pre-set languages |
| Connections and memory | RS232 for PC connection (optional software); USB for memory stick; Internal memory, storage up to thousands tests. |
| Power supply | 110 V or 230 V, 50 Hz/60 Hz, 2500W |
| Dimensions | 290 mm x 460 mm x 430 mm (W x D x H) |
| Weight | approx. 10 kg |
Features
- Fully automatic softening point determination. The apparatus automatically applies the temperature gradient and detects the specimen position with light barriers, recording the softening point.
- 7’’ colour touchscreen display, with multiple preset and custom testing procedures, allowing real-time display of the temperature / time graph on display or PC (with optional software).
- Inbuilt cooling fan, automatically enabled at the end of the test, to reduce the beaker cooling time.
- Removable transparent front cover, protecting the operator from accidental hot water or glycerol splashing or accidental contact with the hot beaker and plate.
- PT100 probe holder and drip tray for specimen holder, complete with handle, improving beaker positioning operations.
- Possibility to perform user-defined tests with maximum temperature up to 250°C.
Included
| outfit for softening point of bituminous materials (two rings, two steel balls, two centering devices, support frame, 600ml beaker, PT100 probe, sample preparation plate and magnetic stirrer) |
| The apparatus is supplied complete with outfit for softening point of bituminous materials (two rings, two steel balls, two centering devices, support frame, 600ml beaker, PT100 probe, sample preparation plate and magnetic stirrer). |
Ordering information
| 81-PV0144 | Automatic ring and ball apparatus. 230V, 50-60Hz, 1ph |
|---|
Accessories
| 81-PV0145/1 | Brass ring (one piece) |
|---|---|
| 81-PV0145/2 | Steel ball |
| 81-PV0145/3 | Ball centering guide (single piece) |
| 82-P0172/1 | Serial cable for printer connection |
| 81-PV0144/2 | Ring holder assembly for 81-PV0144 |