TerraField logo
Item TF-0OMR2W6

Environmental Triaxial System

Environmental Triaxial System

The VJ Tech Pro Temperature Controlled Environmental Triaxial System delivers automated total and effective Temperature Controlled Triaxial testing for Consolidated Drained (CD), Consolidated Undrained (CU), and Unconsolidated Undrained…

MeetsAS1289.6.4.1 · AS1289.6.4.2 · BS1377-7 · BS1377-8 · BS1377:2-2022 · ISO 17892-7 · ISO 17892-8 · ISO 17892-9
In stock
Price: request quote
Add to quote

Technical specifications

Technical specifications for Environmental Triaxial System
Triaxial Testing Temperature Range20°C to +80°
Maximum Cell Pressure2000 kPa
Sample Sizes diameter (mm)38, 50
AustralianAS1289.6.4.1 (1998 & 2016) AS1289.6.4.2 (1998 & 2016) T171
BritishBS1377-7: 1990 BS1377-8 (1990) BS1377:2-2022 (Clause 28 & 27) BS1377:2-2022 (Clause 29 & 30)
EuropeanBS EN ISO 17892-7 BS EN ISO 17892-8 BS EN ISO 17892-9
AmericanD2166 (-13 & -16) D2850 (-03A & 15) D4767 (-95 & -11) D7181-20
Hong KongGEOSPEC 3

Features

  • Temperature Range from -20°C to +80°C.
  • The system is provide with 9 Analogue and 1 Digital Channel Input
  • Built-in logger allowing high speed sensor data conversion (24 bit, up to 5000 samples/s)
  • Closed Loop control for Displacement, Load, Speed mode and Pressure.
  • Flexibility to adjust PID for a variety of samples, ranging from stiff to soft soils
  • Auto engage function to easily apply seating load
  • Soft limits adjustable for all channels
  • Standalone Use via Touchscreen display with data export to PC
Show 8 more features
  • Built-in live data table and graphs
  • Built-in auto protection for mechanical limits & sensor limits
  • Auto reverse from limit switch activation
  • Multiple Units can be controlled from single PC via a LAN or Ethernet/USB hub
  • USB or Ethernet connectivity for PC Control
  • Consolidated Drained (CD)
  • Consolidated Undrained (CU)
  • Unconsolidated Undrained (UU)

Included

Included for Environmental Triaxial System
VJT5110-PTriSCAN Pro 100 kN Advanced Load Frame
VJT-TEMPCO NTROLTemperature Control Unit: Range -50°C to +200°C; (200-230VAC/50-60Hz)
VJT-TEMPCO NTROL-110Temperature Control Unit: Range -50°C to +200°C; (110V/60 Hz)
VJT2267D-PDual Automatic Pressure Controller (up to 3500 kPa/250cc per Channel)
VJT0549- TEMPTemperature Controlled Triaxial Cell: – Up to 50 mm dia sample size – Temperature Range -20°C to +80°C – Maximum cell Pressure up to 2000 kPa

Accessories

Accessories for Environmental Triaxial System
VJT0271LSCT Displacement Transducer (25 mm)
VJTS0366100 kN S-Beam Load Cell
VJT0260-G20 bar Pressure transducer (2 MPa)
VJT0549-TEMP-38Top Cap and Base Pedestal Set for 38mm dia samples [TEMP
VJT0549-TEMP-50Top Cap and Base Pedestal Set for 50mm dia samples [TEMP]
VJT0280De-airing block with valve for pressure transducer
VJT0280-SOLAutomatic Solenoid Valve (optional)
VJT0281Q-TEMPAdapter set for 100 kN S-Beam Load Cell
VJT-TEMP-FLUIDBath fluid for System
VJT-TEMP-GLYCOLGlycol Mix Fluid for use with Environmental Chamber
Show 2 more items
Additional accessories for Environmental Triaxial System
VJT0505TInstallation Kit for Triaxial System
VJT-csTRIAXClisp Studio Triaxial Software